{"id":3754,"date":"2013-06-07T13:40:46","date_gmt":"2013-06-07T12:40:46","guid":{"rendered":"https:\/\/www.trotec-blog.com\/en\/?p=3754"},"modified":"2015-07-10T09:46:25","modified_gmt":"2015-07-10T07:46:25","slug":"flood-moisture-measurement","status":"publish","type":"post","link":"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-moisture-measurement\/","title":{"rendered":"Trotec Flood Info: The right moisture measurement after flood damages"},"content":{"rendered":"<p><img loading=\"lazy\" class=\"alignright size-full wp-image-3756\" alt=\"VIEW_tro_blog_banner_hochwasser_2013_feuchtemessung_en\" src=\"https:\/\/www.trotec-blog.com\/en\/files\/2013\/06\/VIEW_tro_blog_banner_hochwasser_2013_feuchtemessung_en.jpg\" width=\"700\" height=\"300\" srcset=\"https:\/\/www.trotec-blog.com\/en\/files\/2013\/06\/VIEW_tro_blog_banner_hochwasser_2013_feuchtemessung_en.jpg 700w, https:\/\/www.trotec-blog.com\/en\/files\/2013\/06\/VIEW_tro_blog_banner_hochwasser_2013_feuchtemessung_en-300x128.jpg 300w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2>When the cellar is completely under water it is clear that it has to be dried. But what about the floors above? Can the moisture rise via the capillaries? Is the floor construction soaked? Particularly important is the question when the dehumidification will be over and when you don\u2019t have to expect any consequential damages. Another important fact for you to know is to what extent you can make the dehumidification on your own and when it is necessary to ask an expert.<\/h2>\n<p><!--more--><\/p>\n<p>To answer these and other question you have to measure the moisture in the affected areas. Electronic moisture meters are very reliable and you can distinguish between two measuring principles:<\/p>\n<ul>\n<li>Measurement devices using the resistance principle<\/li>\n<li>Dielectric measurement devices<\/li>\n<\/ul>\n<p>Resistance measuring devices use two electrodes leading current through the building structure to be measured. When the structure is dry the resistance is very high because dry materials conduct current only poorly. The more moisture is in the building structure the more the conductivity rises because water conducts the current pretty well. With this measuring method you can measure the moisture content on the material surface as well as in deeper building component layers to check if a wall is only dry on the surface or, as well, deeper inside the wall.<br \/>\nThe dielectric measurement method uses another principle. With an electrical stray field you use a mostly spherical sensor for a non-destructive measurement that reaches a few centimetres into the building structure.<\/p>\n<h3><strong>What mistakes can happen and when should I ask an expert?<\/strong><\/h3>\n<p>Some factors can falsify the results of both measuring methods. In the building structure contained salt, for instance, can increase the measured value. In such a situation you have to ask an expert.<br \/>\nUsing the resistance measurement you have to be careful not to measure other conductive materials like cables, water pipes etc. because they distort the results<\/p>\n<h3><strong>How do I interpret the measured values?<\/strong><\/h3>\n<p>The measuring devices from the Multi Measure Series, the <a href=\"https:\/\/www.trotec24.com\/en-gb\/measuring-instruments\/humidity\/material-moisture\/t510-moisture-meter.html\" title=\"Trotec24 Online Shop \/ Measuring Instruments\/Humidity\/Material Moisture\/T500 Moisture Meter\" class=\"broken_link\">T510 moisture meter<\/a> for example, show you the results in so called digits. Values under 30 digits say that the building structure is dry. Values over 70 digits mean a strong moisture penetration. Between 30 and 70 digits it is necessary to make an individual decision according to the characteristics of the damage.<br \/>\nOur <a href=\"https:\/\/www.trotec24.com\/en-gb\/static\/error\/\" title=\"Trotec24 Online Shop \/ Measuring Instruments\/Humidity\/Material Moisture\/BM15 Moisture Meter\" class=\"broken_link\">moisture meters BM15<\/a> and <a href=\"https:\/\/www.trotec24.com\/en-gb\/static\/error\/\" title=\"Trotec24 Online Shop \/ Measuring Instruments\/Humidity\/Material Moisture\/BM20 Moisture Meter\" class=\"broken_link\">BM20<\/a> use the resistance principle as well. They just don\u2019t show the results in digits but in per cent by volume.<br \/>\nUsing dielectric measuring devices we have to distinguish between two devices for the evaluation of the measured values. Over 50 digits the <a href=\"https:\/\/www.trotec24.com\/en-gb\/static\/error\/\" title=\"Trotec24 Online Shop \/ Measuring Instruments\/Humidity\/Material Moisture\/BM30 Moisture Meter\" class=\"broken_link\">BM30<\/a> moisture indicator indicates a soaked building structure.<br \/>\nThe <a href=\"https:\/\/www.trotec24.com\/en-gb\/measuring-instruments\/humidity\" title=\"Trotec24 Online Shop \/ Measuring Instruments\/Humidity\/Material Moisture\/T650 Moisture Meter\" class=\"broken_link\">T650<\/a> shows that a building structure is soaked when the value is over 80 digits.<\/p>\n<h3><strong>Which device is right for me?<\/strong><\/h3>\n<p>The dielectric measuring instruments have the advantage that they measure non-destructive up to depths of four centimetres by just putting the spherical sensor on the material surface. Using the resistance principle you have to press the electrodes into the material but with that method you can measure deeper that four centimetres.<br \/>\nWhen your dehumidification is over the measured values should lie clearly under the values mentioned here. Then really everything is dry and you don\u2019t have to be afraid of consequential damages.<\/p>\n<h3><strong>Trotec Flood Info: To inform you in any case of damage<\/strong><\/h3>\n<p>We inform you about the following topics in detail:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-expert\/\" title=\"Trotec Blog \/ Trotec assists flood victims with expertise\">Trotec assists flood victims with expertise<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/trotec-drying-duration\/\" title=\"Trotec Blog \/ How long does a dehumidification take?\">How long does a dehumidification take?<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-rent-or-buy\/\" title=\"Trotec Blog \/ Should I rent or buy a drying unit?\">Should I rent or buy a drying unit?<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-moisture-measurement\/\" title=\"Trotec Blog \/ The right moisture measurement after flood damages\">Trotec Flood Info: The right moisture measurement after flood damages<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-info-expert\/\" title=\"Trotec Blog \/ When do I need an expert\">Trotec Flood Info: When do I need an expert?<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-info-mould\/\" title=\"Trotec Blog \/ What to do when mould attacks?\">Trotec Flood Info: What to do when mould attacks?<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-dry-floor-insulations\/\" title=\"Trotec Blog \/ How to dry floor insulations\">Trotec Flood Info: How to dry floor insulations<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/trotec-flood-info-smell\/\" title=\"Trotec Blog \/ What to do against the smell after the flood damage?\">Trotec Flood Info: What to do against the smell after the flood damage?<\/a><\/li>\n<li><a href=\"https:\/\/www.trotec-blog.com\/en\/trotec\/flood-info-drying-units\/\" title=\"Trotec Blog \/ The main facts about drying units\">Trotec Flood Info: The main facts about drying units<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>When the cellar is completely under water it is clear that it has to be dried. But what about the floors above? Can the moisture rise via the capillaries? Is the floor construction soaked? Particularly important is the question when the dehumidification will be over and when you don\u2019t have to expect any consequential damages. Another important fact for you to know is to what extent you can make the dehumidification on your own and when it is necessary to ask an expert.<\/p>\n","protected":false},"author":65,"featured_media":3757,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,10,126,107],"tags":[104,108,53],"_links":{"self":[{"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/posts\/3754"}],"collection":[{"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/comments?post=3754"}],"version-history":[{"count":14,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/posts\/3754\/revisions"}],"predecessor-version":[{"id":6090,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/posts\/3754\/revisions\/6090"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/media\/3757"}],"wp:attachment":[{"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/media?parent=3754"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/categories?post=3754"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.trotec-blog.com\/en\/wp-json\/wp\/v2\/tags?post=3754"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}